125 mm (five inches) and shall
with
no
evidence
of
be fitted between insulation and
discontinuity. The FRP/plywood
the inner panels.
panels shall be installed with
extruded
aluminum
corner
FPH
HAZMAT PLACARD HOLDERS
posts, top rails, bottom rails and
When code FPH is specified,
side door frames. Panels shall
hazardous
material
placard
be
one-piece.
Vertical
holders in accordance with 40
intermediate body posts shall
CFR Part 172 shall be installed
not be used. Posts, rails and
on each side and each end of
side doorframes shall have
the vehicle.
receiving
edges
providing
attachment to panels with
FRP
FIBERGLASS DELIVERY VAN
fasteners.
Panels shall be
BODY
secured to posts and rails using
When code FRP is specified,
through-fasteners with a head
FRP/plywood van body side and
diameter of not less than 13 mm
end panels shall be provided.
(0.50 inch). Panel edges shall
FRP/plywood panels shall be
be sealed with waterproof
fabricated of one-piece plywood
mastic prior to installation.
core laminate with fiberglass-
Installed panels shall be sealed
reinforced plastic. The plywood
with a high performance silicone
furnished shall equal or exceed
caulking compound on all
U.S. Department of Commerce
enclosing edges. All fastener
Standard
PS
1-95,
C-D
installations shall be waterproof.
(plugged) with exterior glue and
with all plies group 1 species or
FTC
70 GALLONS MINIMUM FUEL
better. Core material shall be
CAPACITY
butted, scarfed or finger-joined
When code FTC is specified,
with joint gaps not greater than
fuel tank(s) totaling not less than
3.2 mm (0.125 inch).
The
265 L (70 gallons) shall be
fiberglass-reinforced
plastic
provided.
(FRP) shall contain not less than
0.51 kg (18 ounces) fiberglass
FTD
100 GALLONS FUEL CAPACITY
woven roving material.
The
When code FTD is specified,
plastic shall be of the thermoset
fuel tank(s) totaling not less than
polyester family of resins. The
380 L (100 gallons) shall be
plastic shall be fully cured under
provided.
heat and pressure to ensure the
FTE
FUEL CAPACITY 200 GALS.
resins from an integral bond to
When code FTE is specified,
the plywood core. The exterior
dual 378 L (100 gallons)
surfaces shall consist of a
capacity tanks shall be providing
gelcoat or tedlar finish of 0.38
a total fuel capacity of 757 L.
mm + 0.08 mm (.015 inch + .003
(200 gallons)
inch).
The gelcoat or tedlar
finish shall be pigmented
FTR
EXTENDED TAPERED FRAME
manufacturer's standard white.
When code FTR is specified, the
Panels shall have an overall
frame rails shall extend and
finished panel thickness of not
shall taper from maximum cutoff
less than 16 mm (0.625 inch).
position so as to form a ramp to
Finished panels shall exhibit a
smooth vehicle exterior surface
Page 47 of 79
to verify that this 7 4Y
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business