cutouts, and a grab handle
rated at 500 pounds per foot of
located under the windshield.
body length.
CPR
CAB PROTECTION RACK
CRT
CARGO RESTRAINING TRACK
When code CRT is specified,
When code CPR is specified, a
cargo-restraining track shall be
cab protection rack shall be
installed
on
each
interior
provided.
The cab protector
sidewall of the van body. The
rack shall be mounted behind
cargo-restraining track shall be
the cab and shall be the full
mounted
in
two
tiers,
width (+2/-3 inches) of the
horizontally on each sidewall.
regular non-sleeper cab. Cab
The first tier shall be located just
protector rack shall be the same
above the scuff plate, the
height (+5/-5 inches) as the
second tier at 2/3 of the wall
regular non sleeper cab. The
height. Each cargo-restraining
cab protector rack for sleeper
track shall be the full length of
cabs shall be a minimum of 86
the van body interior. Tracks
inches wide X 75 inches high.
shall be attached between posts
The cab protector rack shall
through full-length wood fillers,
permit driver visibility of the
to the side wall lining, or not
vehicle rear frame area through
more than 150 mm (6 inch)
the rear window; when a rear
centers. The track fitting holes
window is furnished. The cab
or
slots
shall
be
on
protector rack shall conform to
approximately 64 mm (2-1/2
Federal Motor Carrier Safety
inch) centers. The cargo control
Regulation 393.106.
tracks shall be fabricated of
steel with a thickness of not less
CPR1
CAB PROTECTION RACK, PLUS
than 12 gage (2.657 mm) (1.046
When code CPR1 is specified, a
inch). Two cargo control track
cab protection rack meeting the
bars shall be provided. The
requirements for code CPR and
tracks and cargo control bars
furnished with a locking chain
shall be capable of withstanding
rack, and full width locking tool
a rearward static load of 17.8 kN
tray (minimum 10 inches high
(4,000
pounds)
without
and 8 inches deep) shall be
permanent deformation. Code
provided.
CRT is not available when code
CRP is specified.
CPT
PAINT-CUSTOM COLOR
When code CPT is specified, a
D1
DIFFERENTIAL LOCK OUT
custom or Federal Standard 595
When code D1 is specified, a
color shall be provided.
driver
controlled
differential
lockout shall be provided.
CRP
LOGISTIC POST
When code CRP is specified,
D3
SPECIAL TRACTION
van body sidewall posts shall be
DIFFERENTIAL
the logistic type. Logistic posts
When code D3 is specified, the
shall be minimum 12-gage steel
differential traction control shall
and shall be 1 ¼ inch (nominal)
actuate automatically to ensure
deep; with "E" type logistics slots
that power is transmitted to the
on 4-inch centers land shall be
wheel having traction when the
opposite wheel loses traction.
Page 43 of 79
to verify that this 7 4Y
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business