shall be welded for not less than
entering the cab. The deflector,
50 percent at the contract edges
including exterior mounting and
with the body side rub rails.
supporting hardware, support
ribs
and
the
installation
UPR
PIPE RACK
instructions, shall be securely
When code UPR is specified, a
stowed on the vehicle for
pipe rack mounted on top of the
shipment.
maintenance/line body curbside
cabinets shall be provided. The
UN
UNDERSTRUCTURE, NESTED
DUMP BODY
front of the rack shall permit
When code UN is specified, a
pipes to clear the cab door so
dump
body
with
nested
that the cab door may be
understructure
shall
be
opened with pipes stored in the
provided. The floor of the dump
pipe rack. The rack shall be
body shall directly contact and
equipped
with
adjustable
be supported by the longitudinal
chain/spring hold down devices
sills
as
well
as
the
to secure pipes in transit.
crossmembers.
Longitudinal
URH
ROPE HOOKS
sills shall be capable of
When code URH is specified,
supporting the hoist load.
the maintenance/line body shall
Longitudinal for class D, E, F
have a minimum of four rope
and G shall have a RBM of not
hooks on the inside of a vertical
less than 52,000 N-m (460,000
cabinet in lieu of adjustable
inch pounds). Crossmembers
shelves.
shall provide support under the
floor every 380 mm (15 inches)
URO
OVERHEAD RACKS ONLY
or less.
Each crossmember
When code URO is specified,
shall
pass
through
the
the maintenance/line body shall
longitudinal and be shall be
have
removable
overhead
securely welded to longitudinal.
ladder racks with adjustable
Crossmembers shall have a
brackets.
This option is not
RBM of not less than 12 300
available with option code USS
N.M. (109,000 inch pounds).
or USS2.
Crossmembers shall be capable
of
supporting
an
evenly
USM
SIDE MOUNTED LADDER
distributed load of not less than
RACKS
6800 kg (15,000 lbs) for class C,
When code USM is specified,
9070 kg (20,000 pounds) for
the maintenance/line body shall
class D, 10 900 kg (24,000
have side mounted ladder racks
pounds) for class E body and
with adjustable brackets (Code
1800 kg/m2 (370 pounds per
USM is only available with code
square foot) of floor area for
USS or USS2).
class F
and G bodies.
Longitudinals
and
USS
SUPERSTRUCTURE
crossmembers shall be welded
When code USS is specified,
for not less than 50 percent of
the Maintenance/Line Body shall
the contact edges to the body
be provided with a fixed weather
floor.
Longitudinals shall be
tight roof (superstructure) over
welded for not less than 50
the load space and double doors
percent of contact edges with
at the rear. Inside shelves on
the body ends. Crossmembers
each side of the enclosed
Page 67 of 79
to verify that this 7 4Y
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business