MIL-T-740G
TABLE XIII. Minor defects - 150 defects/100 units. - Continued
Method of
Defect no. Characteristic Defect
inspection
138
139
140
Decals, marking, data and instruction plates Protective coatings
Record forms and publications
Incomplete data, missing, improper location or size Improper application, coverage, materials Missing or improperly processed
Visual Visual Visual
141 Lubrication Improper Visual
1/ Any droplet that occurs at a static fit, metal to metal or gasket combination shall constitute a major defect.
2/ Any drip constitutes a major defect when the vehicle has been standing idle and the components are at ambient temperature.
TABLE XIV. Minor defects - 150 defects/100 units. - Continued
Defect no. Characteristic Defect Method of
inspection
201
202
203
204
205
206
207
208
209
210
Controls Coolant Lubricants Wheels and tires Pulleys and fan Belts
Shock absorbers
Wiring or tubing
Brake system components
Body, cab doors, hood items, stowage
Improper adjustment or assembly
Low or improper mixture
Levels and types improper
(all units)
Improper size; type and mounting
Misalignment; improper mounting
Tension improper;
defective
Improper installation or assembly
Defective; improper installation or coding
Improper assembly, installation, or protection
Improper fits, assembly, or installation;
Visual and functional Visual and functional Visual
Visual Visual Visual Visual Visual Visual Visual
37