MIL-T-62735
(d) All components used in the front wheel drive conversion shall be approved for the conversion application by that component manufacturer doing the conversion.
(e) The converted vehicle shall be certified to conform to FMVSS's No. 108 and 121, by
the intermediate or final manufacturer doing the conversion.
(f) Replacement headlights, if required to be added, shall meet the height requirement of
not less than 560 mm (22 inches) and not more than 1370 mm (54 inches), measured above the road surface, in conformance with FMVSS No. 108. Replacement headlights shall be equivalent in mounting, protection, and range and precision of adjustment to the chassis manufacturer's original production line standard headlights.
(g) Unused headlight cavities shall be covered in a neat workmanlike manner, treated and painted to match the chassis cab color with treatment and painting equivalent to the chassis cab manufacturer's process for the remainder of the chassis cab. Cavities and their covers shall be rustproofed in accordance with 3.10.6.
(h) Complete installation drawings shall be available to the procuring activity. (i) The provisions of 3.5.1 shall not be violated.
3.5.24 Power plant heaters (PPHs). When specified (see 6.2), a coolant heater, an engine oil heater, and fuel warmers (diesel engine driven vehicles only) shall be provided. Heaters shall operate on 110 volt alternating current (ac). Heaters shall be wired through a junction block, including a fuse or circuit breaker, to a single three-pronged (male), weatherproof, slave receptacle for receiving external power and for grounding the vehicle. The receptacle shall be on the driver's side of the vehicle, as near the cab door as practicable.
3.5.24.1 PPH connecting cable. The system shall have a three-wire connecting cable, not less than 7600 mm (25 feet) long. The cable shall be of adequate line capacity to supply power for all heater units simultaneously. The connecting cable shall include a matching female connector at the vehicle end and a standard, three-pronged (two power plus one ground) male connector at the other end. The electrical insulation of the connecting cable shall withstand normal operating stresses in low ambient air temperatures down to -51°C (-60°F) without cracking or loss of dielectric capacity. The vehicle cab shall have provisions for stowage of
the cable.
3.5.24.2 PPH electrical installation. The electrical installation shall conform to FMCSR 393.77(c)(7). Heater lead wires shall not interfere with vehicle component operation and shall have no loose excess wire.
49