* 3.5.4 Interior furnishings. When specified (see 6.2), the interior furnishings, equipment and accessories required by the procuring activity shall be provided. To facilitate installation, the procuring activity will provide copies of necessary specifications, standards, drawings and publications.
* 3.5.4.1 Interior electrical system. Unless otherwise specified (see 6.2), the interior electrical system, including lighting fixtures, switches, wiring system, interior and exterior receptacles, main power distribution panel, power plant equipment and any other electrical accessories shall be the manufacturer's standard. The electrical system shall be in accordance with the National Fire Protection Association NFPA No. 70 and Federal Motor Carrier Safety Regulations 393.30, 393.31 and 393.33.
* 3.5.4.2 Power plant stowage compartment(s). When specified (see 6.2), an airtight power plant equipment stowage compartment(s) of manufacturer's standard type shall be provided. Complete access to power plant equipment shall be provided. If outside door(s) are provided, the door(s) shall be key-operated. Two sets of keys shall be provided.
3.5.4.3 Heating system. Unless otherwise specified, a heating system of the manufacturer's standard type, shall be furnished. When specified (see 6.2), the heating system shall be as required by the procuring activity.
3.6 Safety. All equipment or exposed positions of the equipment which are subject to extreme temperatures or inclement weather, and all rotating or reciprocating parts which are of such nature or located as to become a hazard to operating personnel, shall be insulated, fully inclosed, shielded or properly guarded.
* 3.6.1 Fire extinguisher(s). When specified (see 6.2), fire extinguisher(s) shall be furnished conforming to A-A-393 of type, class, size and UL rating for class B and C fires. Location and type of bracket(s) as required, shall be furnished.
3.6.2 Highway warning kit. When specified (see 6.2), a highway warning kit, including three emergency reflectors, shall be furnished. The highway warning kit shall conform to Federal Motor Carrier Safety Regulation 393.95(f)(2)(i). The kit shall be stowed in the stowage compartment.
* 3.7 Workmanship. Defective components or parts and assemblies which have been repaired or modified to overcome deficiencies shall not be furnished. All parts shall exhibit no evidence of damage, multilation, or poor workmanship. Damaged components or parts that have been subjected to rebuild or repairs shall not be used as replacement parts or components. All mounting devices such as bolts, nuts and rivets shall be complete and secured in accordance with the highest standards of industry.