MIL-C-62310A(AT)
3.4.6 Fuel system, grades and slopes. During vehicle operation, the fuel system shall
maintain a continuous supply of fuel to the engine when ascending and descending 60 percent
grades in forward and reverse gear, and when vehicle is being operated on 30 percent side slopes
with either side of vehicle up slope.
3.4.6.1 Fuel cells. Provision shall be made to assure the internal cleanliness of the fuel
cell(s) prior to initial fueling of vehicle. The fuel cell(s) shall be capable of receiving 50 gallons
of fuel per minute.
3.4.6.2 Fuel and hydraulic lines. Fuel and hydraulic lines and connections shall be internally
clean prior to initial fueling and servicing of vehicle. All fuel and hydraulic lines, connections,
and cells shall be leak-free.
3.4.6.3 Rack linkage. With rack linkage installed in accordance with applicable drawings,
and with the accelerator pushed against the stop, the rack shall be at full open position.
3.4.7 Transmission, transfer gear case and controlled differential. The transmission shall
conform to MIL-T-62099. When installed in vehicle the transmission transfer gear case and
controlled differential shall operate throughout all gear ranges without evidence of leakage.
3.4.8 Ammunition racks (M106A2 and M125A2). Ammunition racks, when installed, shall
support and retain the ammunition, or simulated ammunition of the same size and weight, within
the racks during all conditions of vehicle operation.
3.4.9 Electrical system.
3.4.9.1 Generating system voltage (alternator). After no less than 20 minutes of operation
with headlights on, regulator control shall be observed. Alternator shall be operated at
4000 ± 100 rpm with an output of 50 ± 5 amperes, and the voltage regulator rheostat adjusted to
provide 27.3 ± 0.3 volts at the vehicle batteries. Voltage at the vehicle batteries shall be
28.0 ± 0.5 volts when the load is removed.
3.4.9.1.1 Auxiliary generator (M577A2). The auxiliary generator shall conform to
DAPD-285, and shall deliver 150 amperes continuously for operation of all command post
equipment.
3.4.9.2 Lights Internal and external lights specified on applicable drawings shall operate,
and all electrical contacts and connections shall maintain positive contact, under all vehicle
operating conditions.